- Unit 1: DC Circuits
- Unit 2: Steady State Analysis of Single Phase AC Circuits
- Unit 3: Transformers
- Unit 4: Electrical Machines
- Unit 5: Electrical Installations
Questions in Fundamentals of Electrical Engineering AKTU PYQ 2025-26
- Q1a. Define the following (i) dependent source (ii) linear element (iii) inductance (2 marks, 2025-26)
- Q1a. Define active and passive circuit elements with one example each. (2 marks, 2025-26)
- Q1b. State the Kirchhoff's Current Law (KCL) and Kirchhoff's Voltage Law (KVL). (2 marks, 2025-26)
- Q1b. What is power factor? State its significance. (2 marks, 2025-26)
- Q1c. Define the expression for form factor and peak factor. (2 marks, 2025-26)
- Q1c. What happens to transformer core losses when frequency increases? (2 marks, 2025-26)
- Q1d. What is the condition for series resonance? What happens to the impedance of a series RLC circuit at resonance? (2 marks, 2025-26)
- Q1d. Define slip in an induction motor. (2 marks, 2025-26)
- Q1e. What are the main parts of a transformer and how does it work? (2 marks, 2025-26)
- Q1e. What is the purpose of earthing? List its advantages. (2 marks, 2025-26)
- Q1f. What is the basic principle of a DC motor? What is Back EMF Eb? (2 marks, 2025-26)
- Q1f. State Kirchhoff’s Voltage Law (KVL). (2 marks, 2025-26)
- Q1g. A three phase induction motor has 6 poles and runs at 960 r.p.m. on full load, it is supplied from an alternator having 4 poles and running at 1500 rpm. Calculate the Full load Slip of the induction motor. (2 marks, 2025-26)
- Q1g. Why is RMS value preferred over average value in AC analysis? (2 marks, 2025-26)
- Q2a. Determine the node voltages V1 and V2 for the network shown in figure. (7 marks, 2025-26)
- Q2a. What is meant by unilateral and bilateral elements? Find the current through 1 Ω resistance by using mesh analysis method. (7 marks, 2025-26)
- Q2b. A resistance of 75Ω, an inductance of 0.35H and a capacitance of 150μF are connected in series across a 230V, 50Hz supply. Calculate (i) the resultant current (ii) the phase angle between the resultant current and the supply voltage (iii) power factor of the circuit. (7 marks, 2025-26)
- Q2b. Derive the expression of average power for series R-L circuit. A coil draws 5 A at 0.6 power factor lagging from a 230 V, 50 Hz supply. Determine impedance, resistance, and inductance. (7 marks, 2025-26)
- Q2c. The following results were obtained on a 5 kVA, 2400/120V transformer: Open circuit test 120V, 9.65A, 396W instrument on l.v. side. Short circuit test 92V, 20.8A, 810W instrument on h.v. side. Determine: (i) the circuit constants (ii) efficiency at half load, 0.8 p.f. lagging (iii) regulation at… (7 marks, 2025-26)
- Q2c. Explain the working principle of a transformer and derive the EMF equation. Also derive the condition for maximum efficiency. (7 marks, 2025-26)
- Q2d. How is a rotating magnetic field produced in a three phase induction motor? (7 marks, 2025-26)
- Q2d. Describe the construction and working of a DC motor. A 6-pole wave wound DC generator has 604 conductors. Calculate the generated EMF when the flux per pole is 20mWb and the speed is 500rpm. (7 marks, 2025-26)
- Q2e. Describe the importance of earthing in ensuring electrical safety and protecting equipment. (7 marks, 2025-26)
- Q2e. Explain the working of MCB and ELCB with suitable applications. (7 marks, 2025-26)
- Q3a. Use nodal analysis to determine the voltage across BC and the current in the 12 V source in figure. (7 marks, 2025-26)
- Q3a. Explain the concept of node voltage method. Find the current through 1 Ω resistance by using nodal analysis method. (7 marks, 2025-26)
- Q3b. Determine the current in the 2 Ω resistor of the circuit by Mesh Analysis as shown in figure. [Circuit Diagram: A resistor network with a 60V source, 5Ω, 2Ω, 3Ω, 4Ω, 6Ω resistors, and a 20V source.] (7 marks, 2025-26)
- Q3b. What is meant by linearity in electrical circuits? Calculate current through 5Ω resistance by using KVL. (7 marks, 2025-26)
- Q4a. What is meant by bandwidth of a resonant circuit? Draw the resonance curve of a series RLC circuit and prove the bandwidth is ω₂ - ω₁ = R/L. (7 marks, 2025-26)
- Q4a. Discuss the phenomenon of resonance in series RLC circuits. A series R-L-C circuits has R=20Ω, L=0.2H and C=50µF. Determine Resonance frequency, bandwidth and Quality factor at resonance. (7 marks, 2025-26)
- Q4b. Derive the relation between Phase Voltage & Line voltage for Star connected three phase supply system. A 3 phase, 400-volt supply is connected to a 3 phase star connected balanced load. The line current is 20 amps and the power consumed by the load is 12 KW. Calculate the phase impedance of the… (7 marks, 2025-26)
- Q4b. (i) Explain active, reactive, and apparent power. A circuit draws 10A at 230V with pf = 0.6 lagging. Calculate all three powers. (ii) Derive the relation between line current & phase current for a 3-phase delta connected system. (7 marks, 2025-26)
- Q5a. Explain operating principle of transformer and derive the equation for induced emf in a two-winding transformer. Also discuss the term regulation and efficiency w.r.t. transformer. (7 marks, 2025-26)
- Q5a. A 25 KVA loss less transformer has 500 turns on the primary and 40 turns on the secondary winding. The primary is connected to 3000V, 50 Hz mains determine: (i) primary and secondary current at full load (ii) Secondary EMF (iii) Maximum flux in the core. (7 marks, 2025-26)
- Q5b. The efficiency of a 400 kVA 1-ϕ transformer is 98.77%, when delivering full load at 0.8 p.f. and 99.13% at half of the full load and unity power factor. Calculate (i) Iron loss (ii) Full load copper loss. (7 marks, 2025-26)
- Q5b. Derive the equivalent circuit of a practical transformer. Explain voltage regulation of a transformer with phasor diagram for lagging power factor. (7 marks, 2025-26)
- Q6a. What are the applications of a DC motor? Discuss the factors influencing the selection of a DC motor. A 8 pole lap-wound DC generator has useful flux per pole 0.05 Wb, if the no load voltage at 400 rpm is 300V. Find the number of conductors on the armature periphery. (7 marks, 2025-26)
- Q6a. Explain slip-torque characteristics of a three-phase induction motor. Why is starting torque important? (7 marks, 2025-26)
- Q6b. (i) Why Single Phase Induction Motor is not Self Starting? (ii) What is Synchronous Machine? Also discuss the basic principle of synchronous machine. (7 marks, 2025-26)
- Q6b. Why is a single-phase induction motor not self-starting? Compare synchronous motor and induction motor on the basis of speed, power factor, and applications. (7 marks, 2025-26)
AKTU paper codes: BEE101, BEE201, KEE101, KEE201
Fundamentals of Electrical Engineering previous year papers
More Fundamentals of Electrical Engineering resources
- Handwritten Notes: Unit 1 Handwritten Notes
- Handwritten Notes: Unit 2 Handwritten Notes
- Handwritten Notes: Unit 3 Handwritten Notes
- Handwritten Notes: Unit 4 Handwritten Notes
- Handwritten Notes: Unit 5 Handwritten Notes
- Important Questions: Important Questions (All Units)
- Notes: Unit 1 Notes
- Notes: Unit 2 Notes
- Notes: Unit 3 Notes
- Notes: Unit 4 Notes
- Notes: Unit 5 Notes
More versions of this resource
Browse all notes · Semester 1 notes · Semester 2 notes · Electrical Engineering notes